2.4.6.1 Power On/Off
This command controls the power on/off state of the amplifier.
Syntax: Px
Parameters: State(x):
0 = power off
1 = power on
Response Format: None (No query for this command)
Example: To turn the power on, send the following command: P1<LF>
To turn the power off, send the following command: P0<LF>
2.4.6.2 Gain
This command sets the gain level of the amplifier with 4095 steps of resolution.
Syntax: Gxxxx
Parameters: Gain(xxxx):
xxxx = 0000 to 4095
Where:
0000 = Minimum gain
4095 = Maximum gain
Response Format: Same as command syntax
Example: To set the amplifier to minimum gain, send the following command: G0000<LF>
To set the amplifier to 50% Gain, send the following command:G2048<LF>
To find out the gain setting of the amplifier, send the following query: G?<LF>
Response: G3075<LF> (3072 = 75% Gain)
2.4.6.3 Reset
This will clear all faults, if possible.
Syntax: R
Parameters: None
Response Format: None (No query for this command)
Example: To clear any faults, send the following command: R<LF>