PL7004 Kit
Rev F 25
Command To Probe Kit
Response From Probe Kit
Read Probe Interface
Identification command
*IDN?<CR>
Response structure:
<manufacturer>,<model>,<firmware rev level>
<f>,<m>,<r><termination>
where:
, = Separator character ASCII comma
f = manufacturer, AR or AR WORLDWIDE (1 to 18 characters)
m = Interface model designation (1-6 characters)
r = Firmware revision level (0-10 characters)
termination = Depends on the selected response termination
characters (see TERM command for details) (1 or 2 characters)
Total number of characters is variable
.
Read Probe Interface Serial
Number command
SN?<CR>
Response structure:
<serial number>
<s><termination>
where:
s = serial number (1 to 10 characters)
termination = Depends on the selected response termination
characters (see TERM command for details) (1 or 2 characters)
Total number of characters is variable.