Vertical foam markers
5.6 Mounting the pneumo-hydraulic circuit
- Connect the white tube (air) and the blue tube (uid) to the foam marker which is the farthest from
the compressor unit. Ensure that each tube is connected to a connector of the same color.
- Lay the piping along the framework of the boom as far as the electric compressor unit, leaving
plenty of it by the joints.
- Connect the tubes to the compressor unit ensuring that each tube is connected to a connector
of the same color.
- Connect the foam marker which is the nearest to the compressor unit and repeat the above
procedure.
- Connect the dark blue pipes (liquid) and the white ones (air) to the ttings of the same colour on
the tank cap.
- Cap the tank.
• Drill two Ø 6 mm holes at a distance of 100 mm
on bar (A).
•Fix the bracket (B) to the bar with the supplied
M6 screws.
•Fit the foam maker (D) onto the knurled section
of the bar (B) and x with the supplied screw
(E).
•Repeat the operation with the other boom.
Fig. 7b
Fi g. 8