Arctic Essentials Owners Manual
9
For 240 (4 wires)
Correct wiring of the
electrical service box,
GFCI, and pack terminal
block is essential.
Call an electrician
if necessary.
For 120 ( wires)
*If connected to a
3 wire system, no 240
component will work.
Electrical wiring: orth American model
n.ye.ce 20 or 20/400
Correct wiring of the electrical service box, RCD,
and pack terminal block is essential!
Call an electrician if necessary.
Electrical wiring: in.ye European model
1-phase
Connect P1 between P
and P13. Connect P2
between P10 and P4.
2-phase
with single neutral
Connect P1 between P
and P10. Connect P2
between P13 and P4.
3-phase
with single neutral
Connect P1 between P
and P10. Connect P2
between P11 and P13.
3-phase Delta
Connect P1 between P
and P10. Connect P2
between P13 and P4.
3-phase Delta
Connect P1 between P
and P10. Connect P2
between P13 and P4.
n.yt.ce 20 or 20/400
Correct wiring of the electrical service box, RCD,
and pack terminal block is essential!
Call an electrician if necessary.
Electrical wiring: in.yt European model
1-phase
Connect P1 between P
and P13. Connect P2
between P10 and P4.
2-phase
with single neutral
Connect P1 between P
and P10. Connect P2
between P13 and P4.
3-phase
with single neutral
Connect P1 between P
and P10. Connect P2
between P11 and P13.
Warning
In.ye.ce models must always be connected to a
circuit protected by a Residual-Current Device
(RCD) having a rated operating residual-current not
exceeding 30 mA.
Warning
In.yt.ce models must always be connected to a
circuit protected by a Residual-Current Device
(RCD) having a rated operating residual-current
not exceeding 30 mA.
P2
P2
P1
N
L1
G
N
P2
P1
L1
L2
G
L3
P2
P1
L1
L2
G
N
P2
P1
L1
L2
L3
G
N
L1
P1
P2
G
N
L1
L2
P1
P2
G
N
L3
L1
L2
P1
P2
G
L3
L1
L2
P1
P2
G
Refer to wiring diagram in the enclosure box lid for more information.
Refer to wiring diagram in the enclosure box lid for more information.
Refer to wiring diagram in the enclosure box lid for more information.
5V[L!;VJVU]LY[TVKLS[VH=Z`Z[LT[OL^OP[LJVTTVU
accessory wire must be moved. See wiring diagram for details.