10

Series Techoo
Heater connections
heat.wav heater
All Series systems come with a high performance
heat.wav heater. With no pressure switch, it features
in.flo integrated dry-fire protection.
Connections for all
240  heaters
(orth American
installations only)
BROWN wire must be
correctly and completely
connected between P12
and P9.
Connections for all
120  heaters
BROWN wire must be
correctly and completely
connected between P12
and P10.
The heat.wav heater is factory configured for
240 / 4 kW, but it can be converted to a dedicated
120 / 1 kW by simply adding a cable connection
(Part : 991-101959).
(120 conversion is available on North American in.ye-3
models only).
heat.wav specification summary:
Supports 120 or 240
Protected by external breaker (not fused)*
Incoloy heater element
Optional 5.5 kW (Part : 9920-101449),
240 heater is available.
All heater connections are accessible when the cover is removed. Connections include the in.flo dry-fire protection,
hi-limit/regulation probe connectors, power and ground cable connections.
5V[L!,\YVWLHUTVKLSZHYL=VUS`
and are fuse protected
LiveGroundin.floReturnRegulation probe
For early North American
version installations
the ELLOW wire must be
between P25 and P20.
the ORANGE wire must be
between P24 and P1
Note:To convert model to
H=Z`Z[LT[OL^OP[L
(common) accessory wire
must be moved. See wiring
diagram for details.