AUTOMATIC OPERATION
HEATING
HEATING PERFORMANCE
A heat pump conditioner heats a room by taking heat from
outside air. The heating efficiency will fall off when the
outdoor temperature is very low. If enough heat is not
obtained with this air conditioner, use another heating
appliance in conjunction with it.
For several minutes after the start of heating operation, the
indoor fan will not run until the indoor heat exchanger coil
has warmed up sufficiently. This is because the COLD
DRAFT PREVENTION SYSTEM is operating.
During this period the standby lamp will be light up.
DEFROSTING OF HEAT EXCHANGER
OUTDOOR UNIT “STANDBY”
When the outdoor temperature is low, frost or ice may
appear on the heat exchanger coil, reducing the heating
performance. When this happens, a microcomputer
defrosting system operates. At the same time, the fan in
the indoor unit stops and the OPERATION lamp is flashing
until defrosting is completed. Heating operation restarts
after several minutes. (This interval will vary slightly
depending on the room and outdoor temperature).
HOW TO SET THE PRESENT TIME
1. Press the SET button for five seconds. The time
indication alone flashes.
2. Press the + or - buttons until the present time is
displayed.
3. Press the SET button to stop the indication flashing.
COOLING
Verify that the unit is connected to the
main power and the STANDBY lamp is
light up.
1.Set the MODE selector to COOL
.
2.Press the ON/OFF button and switch
the air conditioner ON.
3.Press the TEMP. buttons (3) to set the
desired temperature (the temperature
range is between 30 °C max. and 16
°C min.).
NOTE
THE DISPLAY
SHOWS THE
SELECTED
TEMPERATURE.
4.Press the FAN SPEED button to select the fan speed.
5.Press the FLAP buttons and adjust the air flow direction as
desired (see adjustment of air flow).
1.Set the MODE selector to HEAT .
2.Press the ON/OFF button and switch the air condioner
ON.
3.Press the TEMP. buttons (3) to set the desired temperature
(the temperature range is between 30 °C max. and 16 °C
min.).
4.Press FAN SPEED selector button to the setting you want.
5.Press the FLAP button and adjust the air flow direction as
desired (see adjustment of air flow).
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
1
5
4
3
2
1.Set the MODE selector to AUTO .
2.Press the ON/OFF button and switch the air condioner
ON.
3.Press the TEMP. buttons (3) to set the desired temperature
(the temperature range is between 30 °C max. and 16 °C
min.).
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
When this setting is selected, the air conditioner calculates
the difference between the thermostat setting and the room
temperature and automatically switches to the COOL or
HEAT mode as appropriate.
4.Switch the FAN SPEED selector button to the setting you
want.
Example of operation diagram in the (Auto) mode with
the set room temperature at 23°C.
ONON ON
1 H 1 H
MIN. MAX.
A
B
C
C
B
A
27
26
25
24
23
22
21
20
19
NOTE