This document describes the Argo Lilium Evo 11 and Lilium Evo 13 dehumidifiers, designed for domestic use. These appliances are highly efficient and utilize R290, a natural refrigerant with a low global warming potential (GWP) of 3. R290 is a non-polluting refrigerant that does not harm the ozonosphere and has no effect on the greenhouse effect, offering high energy efficiency. While flammable, its flammability is very low and it can only be ignited by fire.
The primary function of these devices is to dehumidify the air, removing excess moisture to improve indoor air quality and comfort. The dehumidifier operates by drawing in air, extracting moisture, and then releasing warmer, drier air back into the room. It is designed to operate within ambient temperatures ranging from +5°C to +32°C. At lower temperatures, ice may form on the evaporator, triggering a defrost mode where the compressor stops and the fan continues to run until the ice melts.
The dehumidifier offers multiple operating modes:
The device features an auto-restart function, allowing it to resume operation automatically after a power failure.
The dehumidifier is controlled via a user-friendly panel with a display and several buttons. The display shows the relative humidity setting and timer setting. LED indicators provide visual feedback on the device's status, including:
The control panel also features a front LED that changes color based on the room's humidity level: blue for humidity below 50%, green for humidity between 50% and 70%, and red for humidity above 70%.
The device requires proper placement, at least 1 meter away from flammable or heat-sensitive materials and 50 cm away from walls or other obstructions, to ensure correct heat dissipation and optimal performance. It must be kept vertical at all times, especially after unpacking, to allow the refrigerant to stabilize for at least two hours before operation.
Condensate can be collected in a removable front tank. When the tank is full, the unit automatically shuts off, and the "TANK FULL" LED illuminates. The tank must be emptied and correctly reinstalled for the dehumidifier to resume operation. For continuous drainage, a PVC hose (17 mm internal diameter, 19 mm outer diameter, and 30 cm length) can be connected to the drain hole. It is crucial that the drainage hose's height does not exceed that of the hole and that the exit is not blocked.
For safety, the appliance should not be moved while operating, as this can cause leaks and malfunctions. It should also not be tilted or turned upside down. The unit is equipped with a child lock function, activated by pressing the "+" and "-" buttons for 3 seconds, which disables the control panel buttons.
Regular maintenance is essential to ensure the dehumidifier's efficiency and longevity.
In case of any anomaly or malfunction, the appliance should be switched off and unplugged immediately. Users should not attempt to dismantle, repair, or modify the product themselves. All repairs should be carried out by an authorized after-sales service center.
| Dehumidification Capacity | 11 liters/day |
|---|---|
| Refrigerant | R290 |
| Air Flow | 120 m³/h |
| Power Consumption | 200 W |
| Tank Capacity | 2 liters |
| Operating Range | 5°C to 32°C |
| Sound Power Level | 42 dB |