3. Technical Features
Refrigerant .......................................... R134a
Electronic refrigerant scale ..................+/- 10 g resolution
Load cell ............................................. 60kg with 150% overload capacity
LP and HP gauges ..............................AI-D 68 mm kl.1.0
Recovery cylinder ................................12 kg (25kg on heavy duty model)
Recovery pump ................................... AI-FR11G, 275W
Recovery rate ...................................... 380 g/min (liquid state)
Vacuum pump ......................................2 stage, 75 l/min, (140 l/min available on request)
Vacuum ................................................5 x 10
-1
Pa
Filter dryers (main) ...............................AI 162-1/4" (x 1)
Filters dryer (primary)…………………...AI 032-1/4" (x 2)
Dimensions ...........................................W- 580 mm, (23”) D- 620 mm (24,1/2”) H-1090 mm (43)
Weight .................................................. 75 kg (180lb)
Chassis ................................................ Sturdy all steel construction powder coated.
Supply voltage ..................................... 230V/ 50Hz (110V/ 60Hz available on request)
Noise level ............................................< 70 dB (A).
Fixed wheels……………………………..200mm (8”) Heavy duty oil resistant
Caster wheels…………………………....75mm (3”) Heavy duty oil resistant