Page 26
Aries Spas • User Manual
Note: The above method of starting a siphon only works
when the faucet is below the water level of the spa.
Anotherwayofemptyingyourspaistousethefaucetorspigotthatis
builtintoyourAriesSpa,attachedtotheequipmentpack.Openthevalve
(turnthespigot).Itisbestifyouattachagardenhosetothefaucet,keep-
ingthewateroffoftheEquipmentPack.Thewaterwillstarttodrainout
aslongasthefreeendofthehoseisbelowthewaterlevelofthespa.
Note: The above method will drain the water only to the
level of the lowest circulating tting in the spa (the lowest
Bottom Suction). The remaining water will have to be siphoned
(as described above) or bailed out.
Troubleshooting Guide
Problem Possible Causes/Solutions
Spa Equipment does not operate. Nothing works.
GFCI has possibly tripped or may be turned off.
ResetGFCIonspapackbypushing“On”.IfGFCIresetsforamo-
ment,thentripsagain,see“Blowerdoesnotwork”below.
Household circuit breaker has tripped.
Switchbreakerto“Off”position,thenresetto“On”.
Equipment is not wired correctly, or isn't provided with
proper power.
Ifyouhavequestionsaboutwhetheryourspaiswiredcorrectly,call
yourspadealerorthefactory.
Fuse has blown
Checktoseeiffusehasblown.FuseislocatedabovetheGFCIon
therightsideoftheequipmentpack.Iffuseisblown,itcanonlybe
replacedwithAGC1/2,250volt,quick-blow(glass)fuse,availableat
Aries'Store,somehardwarestores,RadioShack,etc.