Page 33
Aries Spas • User Manual
ously.ItisrecommendedthattheCirculatingPumprunscontinuallyso
thatyourOzoneGeneratorcanoperateround-the-clock.
Algaehasgrowninthepipingsystemofthespa.MakesureOzona-
tor(ifsoequipped)isworkingproperlyorthatsanitizersareatthe
properlevel.UseSpaAlgaecidetokillalgaeandcontinuetousein
maintenancedosestokeepitfromreturning.Ifnecessary,usetheDeep
CleaningofPlumbingLinesmethodintheMaintenanceSectionofthis
manual.
Trouble Codes
IfyourcomputerizedEquipmentPacksensesaninternalproblem,itwill
putanerrorortroublecodeinthedigitalreadoutareaofyourTopside
Control.Followingarethemostcommonerrorcodes,andthesolutionfor
each.
" -- " " [temp] " (two bars ashing, alternating with your spa's
temperature ashing).
This appears when there is a low ow volume through
the heater. The most common cause is a clogged or
embedded lter cartridge. Try running the spa without a
lter cartridge (see section on lter cleaning for removal
of your cartridge) for a few hours. If the problem persists
with no lter, contact an Aries Spa Technician.
" ---" "39" (three bars ashing alternately with 39)
This appears when there is a defective or damaged
temperature sensor. Contact an Aries Spa Technician.
" [temp]" (your spa's temperature ashing)
This appears when the spa's water has gotten too hot.
Please refer to the Troubleshooting Guide "Your Water
is too hot", and "Customized Circulation Mode" in the
operating section of this manual.