OTHER FEATURES
AUTO-RESTART
If the unit shuts off unexpectedly due to a power outage, it will restart with the previously set function
automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it cannot be restarted until 3 minutes time has elapsed. This is to protect the unit.
Operation will automatically resume after 3 minutes.
AIRFLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the air fow direction automatically.
● When the Power is ON, the louver opens fully.
● Press the SWING button on the remote controller to initiate the Auto Swing feature. The louver willl swing
up and down automatically.
NOTE:The louver will swing right and left or up and down.or the vertical louver is adjusted by manually.
(Specific functions to the actual machine to prevail)
SELF-DIAGNOSIS
The appliance has a self diagnosis system to identify a number of malfunctions.
Error messages are displayed on the appliance display
●PF-temperature sensor error((sensor damaged) - call for service.
●FT-Bottom tray is full (safety tank full) - Connect the drain hose and drain the collected water away.
WATER DRAINAGE
When there is excess water condensation inside the unit, the appliance stops running and shows
“LT”(Bottom tray is full as mentioned in SELF-DIAGNOSIS). This indicates that the water condensation
needs to be drained using the following procedures:
●Manual Draining
1. Unplug the unit from the power source.
2. Carefully move the unit to drain area over your basement
floor or drip pan(locally purchased).
3. Remove the botton drain cap.
4. Let the water drain away and replace the drain cap
5. Restart the machine until the symbol “FT” disappears
If the error repeats,call for service
NOTE:Be sure to reinstall the botton drain cap before using the unit
●Continuous Draining
1. Unplug the unit from the power source.
2. Remove the botton drain cap.While doing this operation
some residual water may spill so have a drip pan(locally
purchased)to collect the water
3. Connect the drain hose as shown in the diagram.The water
can be continuously drained through the hose into a floor
drain or drip tray
4. Turn on the unit