22 ExTensor
Login
(Contd.)
A user has to be selected/logged in on initial switch on or after a voltage loss, even if no password was given for the
selected user.
If no password was stored for the user, the password entry is skipped and the first menu item will be displayed.
Password entry:
Select the appropriate figure via buttons L & R (actual figure is flashing)
To edit the figure press the MENU button --> An underscore is shown below the figure.
Set selected figure by using buttons L & R.
Confirm the set figure with the MENU button.
Navigate to the confirmation arrow after password entry and confirm with the MENU button.
No error message is shown when entering a wrong password. A correct password or the active user is marked with an
asterisk (*) behind the selected user.
Example with user "User":
Password correct/User active: > User*
Password wrong/User inactive: > User
End positions End positions
Selection and setting of the left (EL) and right (ER) end position.
Approach end positions using buttons L and R and then store them.
Procedure:
Select the end position to be set
Within the display "<EL>" or "<ER>" approach left resp. right end position via buttons L & R and confirm with
MENU button
Accept (Y) or cancel (N) storing the end positions. Change between (Y)/(N) via buttons L & R, confirm selection
with MENU button.
Motor or parts can be damaged when driving against obstacles. The motor does not stop at the prior set end positions
during an end position is re-programmed. Drive the actuator slowly and carefully when setting new end positions.
Left and right end positions can be interchanged. The assignment of the turning direction of the inputs 2/3 and the
buttons LI/RE do not change.
The end positions must be 28° apart due to technical reasons. If the difference range is too small, the actuator will
prompt "Error Code 51".