36 ExTensor
7. Options
more options - mechanichal poti, terminals ... ?
8. Maintenance and service
ARIS actuators of the ExTensor series have permanent lubrication and are basically maintenance-free. We recommend carrying out
a function test and a visual inspection once a year.
Repairs: No repairs or mechanical processing of any kind may be carried out on the gap surfaces of the ameproof gaps. In
particular, the cover/housing gap surfaces must not be changed.
Non-observance can lead to serious accidents and damage to property - The ATEX/IECEx
Approval for the device expires in the event of non-compliance or misuse.
Cleaning
Only clean the actuator with a damp cloth. Never clean with a high-pressure cleaner.
Pressure proof encapsulation
Before opening, ensure that there is no gas and no voltage
Joint surfaces must not show any damage or contamination
The hood must not tilt during assembly
Regular maintenance work:
The type and scope of the tests correspond to the relevant national regulations (e.g.
IEC/EN 60079-17).
The deadlines are calculated in such a way that any defects that are to be expected
be identied in a timely manner.