1.5. PROfessional TECH PTEC steatite range
1.5.a. Definition of the range
Heating element: Steatite heating element
located inside a bush
Anti-corrosion protection: Enamelled boiler +
PROfessional TECH anode
The exclusive PROfessional TECH system solution
is an anodic anti-corrosion electronic protection
system with a modulated current. It ensures
maximum durability in terms of the boiler used
in the water heater, regardless of whether more
or less aggressive water is used. The electronic
circuit creates a difference in potential between the
boiler and the titanium electrode, so that optimal
boiler protection is guaranteed, thereby preventing
its corrosion.
Picture 3- Steatite heating element + PROfessional TECH
anode
1.5.b. Technical features
See page 2.
In s t a l l a t I o n
1. Legal obligations and recommendations
relating to product installation
Before installing this appliance, please read the
instructions contained in this manual carefully.
Failure to observe these instructions may lead to
the guarantee becoming void.
1. All product installation and maintenance work
must only be performed by qualified professionals.
Current national legislation must be observed. In
particular, all regulations relating to water heaters
must be fully observed.
2. The manufacturer shall not be held liable for
any damage caused by unprofessional or improper
installation, or by failure to comply with the
instructions contained in the user manual.
3. The appliance and its safety assembly must be
installed in a room which is not subject to freezing
conditions.
4. When performing maintenance work, the
following should be provided:
a. a free space of at least 50 cm in front of the
plastic cover so that the electrical components
may be accessed;
b. direct access to the safety assembly.
5. If the appliance is installed in a room which
is just above an inhabited space (a loft, attic,
false ceiling, etc.), insulate the piping and fit a
retention tank with water drainage. Connection
to the sewage system is compulsory in all
instances.
To avoid excessive energy consumption,
we recommend that the water heater is
positioned as close as possible to the
hot water drawing points (recommended
distance: no greater than 8 metres).
6. Recommendations for installation in a bathroom
environment (NF C15 100)
1
Definition
Casing volume (A): The casing volume is the
volume outside the bathtub or the shower tray and
is limited, on one side, by the vertical cylindrical
surface circumscribed to the bathtub or to the
shower tray and, on the other, by the horizontal
surface situated 2.25 m from the bottom of the
bathtub or shower tray.
Protection volume (B): The protection volume is
the volume of accessibility which can be touched
directly by the individual in the bathtub or the
shower tray, and is outside the casing volume. It
is limited by the vertical cylindrical surface 0.60 m
away from the edge of the bathtub or shower tray
and by a horizontal surface situated 2.25 m above
the bottom of the bathtub or shower tray.
Picture 4 - Installation area / A : Casing volume /
B: Protection volume
A : Magnesium anode / B : Spike / C : Immersion heating element / D : Plate / E : Bush / F : Steatite heating element /
G : PROfessional TECH anode.
1 «This regulation applies in France and the installer must keep up to date with all subsequent modifications. For installation
in other countries, please refer to applicable local regulations.».