TECHNICAL CHARACTERISTICS
For the technical specications, refer to the nameplate (located on the right side of the water heater).
PRODUCT INFORMATION
MODEL
AURES
EASY 3.5
AURES
EASY 4.5P
AURES
EASY 4.5D
AURES
EASY 2.4
Power (kW)
3,5 4,5 4,5 4,5
Voltage (V)
220
Phases
Mono
Installation
Single point
Construction
Open outlet
Frequency (Hz)
50
Electric current (A)
15,9 20,5 20,5 10,9
Water Protection
IPX25
Pipe Connection
1/2" BSP
Min water pressure (kPa)
20 15 20 20
Max water pressure (kPa)
380 380 380 380
Weight (kg)
1,7 1,8 1,7 1,7
Dimensions (mm)
296 x 233 x 104
INSTALLATION
Caution before installation
1. This heater must be permanently connected to the direct main current supply. The use of a plug
and socket is not recommended.
3. For the correct size of wire conductor corresponding to dierent electrical loading, please refer
to table1.
4. This heater operates at a minimum and maximum water pressure as per table of Technical Char-
acteristics.
5. This heater will not function if there is insucient water ow to trigger the ow switch.
6. The built-in ELCB will automatically cut o the power supply in case there is a current leakage
above 15mA.
7. The thermostat will automatically cut o the power supply if it has sensed an abnormal rise in
showering water temperature. Only qualied technicians are allowed to reset the thermal cut-
out built inside the appliance.
8. To avoid accidentally scalding, user is advised to operate the heater at least a min inlet water ow
of 2 l/min.