installation
Before the boiler is used for the rst time,
the trap must be lled with water. To do this,
add approximately 1/4 litre of water via the
ue outlet before tting the ue system, or
unscrew the cap on the trap positioned under-
neath the boiler, ll it with water and ret it
Warning! Insucient water in the trap can
temporarily cause the ue gas to be expelled
into the surrounding ambient air.
Water circuit diagram
2
1
4
3
6
7
8
5
A
B
C
1. C.H. ow temperature probe
2. C.H. return temperature probe
3. Burner
4. Detection electrode
5. Condensate trap
6. Modulating fan
7. Ignition electrodes
8. Thermal fuse