MAINTENANCE GUIDE
3.3 MAIN HEAT EXCHANGEUR
Tools
Time
20 min
1
Remove the two clips and dis-
connect the two pipes
Disconnect electrical gas valve,
and electrode (detection and
ignition)
Remove the four screws and
disconnect the gas pipe from the
gas valve
Remove the four screws to free
the heat exchanger
2
Pull the heat exchanger towards
you
Twist the thermal fuse to remove