55
maintenance guide
3.14 TEMPERATURE SENSORS & OVERHEAT THERMOSTAT
TEMPERATURE SENSORS & OVERHEAT THERMOSTAT
Tools Time
5 min
1
Unplug the electrical connectors
Remove the clips and the
temperature sensor or
overheat thermostat together
IMPORTANT!!!! Do not use conducting paste for the contact sensors because it will alter the resistance value.
TEMPERATURE (°C) RESISTANCE (kOmh)
027
10 17
20 12
25 10
30 8
40 5
50 4
60 3
70 2
80 1,5
Temperature sensors & overheat thermostat