/ 15
¡IMPORTANT!
If the unit is installed in areas with the
presence of hard water (> 200 mg / l) is
necessary to install a water softener to
reduce the precipitation of limestone in
the heat exchanger.
The warranty does not cover damage
caused by the limestone.
¡IMPORTANT!
Do not activate the device without the lter.
Water connection
Theillustrationshowstheconnectionsforthewaterand
gasattachmentsoftheappliance.
Checkthatthemaximumwatermainspressuredoesnot
exceed10bar;ifitdoes,apressurereducingvalvemust
beinstalled.
Ensurethattheminimumpressureisnotlowerthan0,2
bar.
View of the hydraulic Connections
A. Hotwateroutlet1/2”
B. IngressoGas1/2”
C. Coldwaterinlet1/2”
Thedeviceisequippedwithalter,locatedonthecold
waterentrance.Periodicallycleanthehydraulicsystem,
ifdirtispresent.
Itisalsoimportanttocheckthatthepressureofthegas
(methaneorLPG)youwillbeusingtofeedtheappliance
issuitable,because if itisinsufcient the powerofthe
generatormaybereduced,causinginconvenienceforthe
user.
Connection of ue gas discharge ducts
Theappliancemustbeconnectedtoauegasdischarge
system that complies with the regulation in force and
instructionsprovidedbythemanufacturer.
WHEN TYPE B INSTALLATION IS USED, THE ROOM
IN WHICH THE APPLIANCE IS INSTALLED MUST BE
VENTILATED USING A SUITABLE AIR INLET WHICH
COMPLIES WITH CURRENT LEGISLATION.
Wheninstallinganexhaustsystem,takecareoftheseals
topreventanyuegasleakingintotheaircircuit.
Make sure that the combustion products are properly
expelledbymeasuring theCO2 contentatthenominal
heatoutput.Thisvalueshouldnotexceedthatindicated
intheTechnicalDatatable.
Ifthevalueisgreater,checktheefciencyoftheuegas
exhaustsystem.
IfitisnotpossibletobringtheCO2valuewithinthelimit
indicated in the Technical Data table, do not start the
appliance.
ATTENTION
NEVER TAMPER WITH OR DECOMMISSION
THE FLUE GAS SENSOR. THIS COULD
AFFECT THE PROPER OPERATION OF THE
APPLIANCE.
POOR DRAUGHT CONDITIONS COULD
CAUSE EXHAUST GAS BACKFLOW INTO THE
INSTALLATION ROOM.
HAZARD OF CARBON MONOXIDE
INTOXICATION.
The part of ue pipe that pass through the wall
of dwelling should be surrounded by insulated
material (such as asbestos cloth) at least 11
mm thickness and 300 mm length since the
temperature of ue pipe maybe exceed the
ambient temperature by more than 60K.