EasyManua.ls Logo

Ariston microSYSTEM 10 RFFI

Ariston microSYSTEM 10 RFFI
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
1. 5. 2 Removing the safety valve
1. Loosen nut Y (F
IG. 1.33);
2. Disconnect the discharge pipe work from below the
boiler;
3. Unscrew and remove the valve.
1.5.3 Removing the automatic air vent
1. Unscrew valve top Z (FIG. 1.34);
2. Remove valve complete with float (F
IG 1.35).
FIG. 1.33
FIG. 1.34
Y
Z
FIG. 1.35
Impor
tant!
Before any component is removed, the boiler
must be drained of all water.
1.5 ACCESS TO THE WATER CIRCUIT
FIG. 1.31
W
FIG. 1.32
X
1.5.1 Removing the pump pressure switch
1. Remove the cable of the pump pressure switch W
(Fig. 1.31);
2. Unscrew the pump pressure switch by using a spanner
on the nut X(F
IG. 1.32);
3. Remove the pump pressure switch.