2. The fridge fan is controlled by the ON / OFF point of each mode.
3. Fridge DIFF. [ON / OFF] 0.5 °C
(mean OFF point: fridge: 1.3°C)
If TA </=13°C, FRIDGE SET is OFF, the set-point increases by 2°C and the mean OFF point of the fridge is
3.3°C.
4. Preventing low/insufficient refrigeration condition
If a condition of insufficient refrigeration is detected the compressor will start, irrespective of the reading
of the Freezer probe.
If the refrigerator probe reaches the fridge fan OFF point, the compressor is controlled by the
refrigerator probe and the fridge fan switches off.
The insufficient refrigeration detection point is the OFF point of the refrigerator probe for each mode
+7°C.
Stop position: same OFF point of the refrigerator probe as that of each mode.
5. Control point of each mode
Y axis = Temperature
X axis = Mode
A. Compressor ON alarm point with threshold
of compressor OFF +7°C
B. ON point. "Control" function of fridge fan
with fridge probe (fan at 12V or 14V).
C. OFF point
D. Phase Diff.
E. Phase Diff.
1. Low
2. Medium-low
3. Medium
4. Medium-high
5. High