EasyManua.ls Logo

Ariston MSZ 70 NF COOLING 2004 - System Operation Overview

Ariston MSZ 70 NF COOLING 2004
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Merloni Elettrodomestici
Instruction Manual Language Edition Page
Side-By-Side Refrigerator – Ariston MSZ 70 NF EN 2004.11.11 9 - 88
1
1
.
.
4
4
.
.
O
O
P
P
E
E
R
R
A
A
T
T
I
I
N
N
G
G
P
P
R
R
I
I
N
N
C
C
I
I
P
P
L
L
E
E
1. Tray temperature sensor (fitted under the ice-cube production tray)
2. Freezer temperature sensor
3. Defrost end temperature sensor (located on the evaporator coil)
4. Refrigerator temperature sensor
5. Room sensor, fitted on the main electronic PCB (the photo shows the PCB
cover located on top of the appliance).
Using measurements and status information supplied by the sensors
(including the fridge and freezer door microswitches), the
microprocessor manages the following systems:
- freezer system
- refrigerator system
- condensation system
- compressor
- defrost system
1 Evaporator and 2 Fans
Air duct
2 separately cooled cavities
Constant temperature cooling
Active Control System