Merloni Elettrodomestici
Instruction Manual Language Edition Page
Side-By-Side Refrigerator – Ariston MSZ 70 NF EN 2004.11.11 73 - 88
3.2.8. R
EMOVING AND
R
EFITTING THE
I
CE
C
RUSHER
S
OLENOID AND
M
OTOR
• The block is located behind the ice maker / container
• Remove the 4 screws (2 on right and 2 on left) that secure the ice maker to the floor of the freezer
• Detach the connector that secures it to the freezer cavity roof
• Extract it by pulling it forwards
• Refit it by performing the steps in reverse
• Solenoid Measurement: approx. 145 Ohm 220 V
• Ice Crusher Motor Measurement: approx. 12 Ohm 220 V
A. Selection solenoid: Cubes - Crushed (commands opening of ice
cubes flap)
Flap Open = Cubes Delivery
Flap Closed = Crushed Ice
B. Auger and Ice crusher Motor
3.2.9. I
CE DISPENSER SOLENOID AND FLAP
• Remove front control panel
• Detach the Front PCB connector
• Remove the 2 screws responsible for fixing the
components cover and remove also the cover
the solenoid is supplied with 220V and has an
impedance of approximately 325 Ohm
the ice outlet cover is operated by the solenoid
• Refit all the parts by performing the steps in
reverse sequence
Operate the switch to check functionality of the
solenoid and the flap