EasyManua.ls Logo

Ariston MSZ 70 NF COOLING 2004 - Presentation of Errors on Display

Ariston MSZ 70 NF COOLING 2004
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Merloni Elettrodomestici
Instruction Manual Language Edition Page
Side-By-Side Refrigerator – Ariston MSZ 70 NF EN 2004.11.11 25 - 88
1.5.8. P
RESENTATION OF
E
RRORS ON
D
ISPLAY
Input Controlled Device
1. Temperature control buttons 88 Display LEDs
1. Start procedure
1) Press the "crushed ice" button 5 times while holding down the "water" button
2) Press the "super freeze" button 5 times while holding down the "freezer set" button
3) Now press the "FREEZER SET" button **
**
INFORMATION SHOWN ON THE DISPLAY:
1. "Appliance powered" minutes
2. Freezer probe temperature
3. Defrost probe temperature
4. Fridge probe temperature
5. Room probe temperature
6. Calibration of pulses for water inlet to ice maker (default value P 100)
7. Residual filter life hours (press Water button to display)
2. Display
If errors occur the relative code is shown on the display.
3. Stopping procedure
1) Press the RESET WATER FILTER button once
2) The system stops automatically 4 minutes after start-up
4. All error codes are reset if normal status is restored
5. Error codes
Fault Code Fault Description
F1
Freezer probe open circuit/short circuit
r1
Fridge probe open circuit/short circuit
rt
Room probe open circuit/short circuit
dr
Defrost probe open circuit/short circuit
d1
Fridge door switch fault
dF
Freezer door switch fault
dH
Homebar door switch fault
C1
Anomalous cycle fault (comp. ON Fz temp. fails to decrease)
F3
Reappears after anomalous/defective defrosting
E1
Ice made probe open circuit/short circuit
EF
Faulty water flow sensor for ice
Et
Switch - Ice maker tray horizontal position incorrect
E9
Water supply for ice (controlled by E1 after 5’)
ES
Water and ice dispensing microswitch faulty
EA
Ice drop simultaneously with fault Et
Eu
Ice maker full sensor fault
d2
Forced defrost mode display (for Service)

Table of Contents

Related product manuals