INPUT Control Object
Main PCB Resistance of R-sensor Mid ON/OFF Point
CONTENTS REMARKS
Regulation of R-sensor ON/OFF point (1.5degree DOWN)
In case refrigeration of refrigerator is weak or insufficient, take the following action.
R-SENSOR
R36
R37
R38
R26 : R-SENSOR standard resistance in normal mode (31.4K )
R37 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K)
R38 : In case of weak ref., cut J19 to down the standard resistance by 1.5deg(2K)
R36 = Mid ON/OFF point
R36 + R37 = Mid ON/OFF point - 1.5 deg
R36 + R37 + R38 = Mid ON/OFF point - 3.0 deg
CONTENTS
3-18. Regulation of R-sensor ON/OFF Point
3-19. Summary of Function
1. Element A/S Function
"freezer set" + "fridge set" 5 times
Forced Defrosting
"fridge set" button 3 sec after first power input
Explanation after delivery
Push "reset water filter" for 3 seceonds.
Reset water filter information
"fridge set" + "water" 5 times
Demo function
2. Special Function
- All the modes are started under test mode.
Test mode : Press "crushed ice" button 5 times while pressing "water" button at the same time.
"freezer set" + "fridge set" + "water" 5 times
Pull Down
"freezer set" + "super freeze" 5 times
ERROR Display function
"water" + "reset water filter" 5 times
EEPROM Clear
"water" + "cubed ice" 5 times
ice maker test