GB
/ 43
1. INSTALLATION
11.1 Installation area
Make sure the installation site and any systems to which
the appliance must be connected comply with applicable
regulations. The interior unit should be installed in an ap-
propriate area with the following conditions:
- Good air circulation;
- Suitable drainage;
- The noise from the interior unit should not disturb other
people;
- Rigid and stable structure: the area should not be sub-
ject to vibrations;
- The structure should be able to withstand the weight of
the unit;
- Observe a distance of at least 1 metre from any electri-
cal appliances (e.g. TV, radio, computer)
The unit should NOT be installed in the following places:
- near any source of heat, steam or combustible gas;
- near any fl ammable objects such as curtains or clothes;
- near obstacles that could obstruct the air fl ow;
- in a room subject to direct sunlight.
The appliance should be installed in a well ventilated area
in which the dimensions of the room are compliant with
the surface area.
FOR MODELS WITH REFRIGERANT R32:
- The appliance should be installed in a room with a
surface area larger than 4 m².
- The appliance cannot be installed in a room with
no ventilation if the surface area is less than 4 m².
1.2 Minimum distances
To ensure the appliance is installed correctly, keep to
the minimum distances indicated in fi gure “A” and leave
enough room for air to circulate freely. Use the accesso-
ries provided with the appliance to carry out the installa-
tion properly.
NOTES:
The dimensions of the internal and external units are giv-
en at the back of the manual.
WARNING:
- Use manual tools and equipment that are suitable
for the intended purpose.
- When lifting loads with a crane or hoist, make
sure the equipment used for lifting is stable and
effi cient and suitably sized for the movement and
weight of the load itself; place the load correctly
in slings, tie ropes around it to limit any oscilla-
tions and lateral movements; lift the load from a
position where there is a full view of all the space
covered by the load during lifting; do not allow
people to pass or stop in the vicinity of the sus-
pended load.
300
250
300
600
300
250
300
300
600
600
Fig. “A”
ø 65 mm
ø 65 mm
ø 65 mm
ø 65 mm
ø 65 mm
ø 65 mm
302 mm
117 mm137 mm
316 mm
716 mm
107 mm
145 mm 254 mm
39 mm
63 mm
11 mm
63 mm
27 mm
297 mm
133 mm112 mm
404 mm
796 mm
128 mm
166 mm 226 mm
39 mm
53 mm
11 mm
53 mm
27 mm
325.4 mm
111 mm
256 mm
439,4 mm
936,6 mm
256 mm
262 mm 262 mm
44 mm
48 mm
48 mm
27 mm