4
Name
CE Cer
tification
Flue Type
Heat Input max/min (Central Heating) kW
Heat Input max (Domestic Hot Water) kW
Heat Output max/min kW
Efficiency of Nominal Heat Input (60/80
°C) %
Efficiency of Nominal Heat Input (30/50°C) %
Efficiency at 30% of Nominal Heat Input (47°C) %
Efficiency at 30% of Nominal Heat Input (30°C) %
Efficiency at Minum Input %
Efficiency (Dir. 92/42/EEC)**
SEDBUK Rating Band
Heat Loss to the Casing (T=50°C) %
Flue Heat Loss with Burner Operating %
Flue Heat Loss with Burner Off %
General Info
Energy Performance
Max Discharge of Products of Combustion (G20) Kg/h
Residual Discharge Head mbar
Temp. of exhaust fumes at nominal capacity °C
CO
2 Content %
O2 Content %
CO Content ppm
Nox Class
Emissions
Head Loss on Water Side (max) (T=20°C) mbar
Residual Head of System bar
Expansion Vessel Pre-load Pressure bar
Maximum Heating Pressure bar
Expansion Vessel Capacity l
Maximum Water Content of System l
Heating Temperature max/min (High temperature) °C
Heating Temperature max/min (Low Temperature) °C
Central Heating
Domestic Hot
Water Temperature (approx) max/min °C
Specific Flow Rate (10 minutes/DT 30°C) l/min
D
.H.W. Flow Rate T=25°C l/min
D
.H.W
.
Flo
w Rate T=35°C l/min
D.H.W. Minimum Flow Rate l/min
Pressure of Domestic Hot Water max/min bar
Domestic Hot
W
ater
Nominal Pressure Natural Gas (G20) mbar
Consumption at Nominal Capacity(G20) m
3
/h
Gas Consumption after 10 Minutes* m
3
Gas
Electrical Supply V/Hz
P
o
w
er Consumption W
Minim
um Ambient
T
emper
ature
°
C
Protection Grade of Electrical System IP
Inter
nal Fuse Rating
Elettrical Data
W
eight
Kg
Dimensions (W/D/H)
mm
G.C. Number
A
CO 27 MFFI
0085BP0229
C13-C33-C43-C53-C83-B23-B33
25,5 / 8,9
27,0
22,5 / 7,7
88,2
88,2
92,9
92,9
86,7
A
0,5
2,6
0,4
35,3
0,61
72
9,1
4,3
109
5
200
0,2
0,7
3
7
130
82 / 42
75 / 20
56 / 36
12,6
15,2
10,8
2,5
6 / 0,2
20
2,43
0,85
1,5
4
1,5
4
230/50
118
+5
24D
40
280/450/750
47-116-34
A
CO 27 RFFI SYSTEM
0085BP0229
C13-C33-C43-C53-C83-B23-B33
25,5 / 8,9
-----
22,5 / 7,7
88,2
88,2
92,9
92,9
86,7
A
0,5
2,6
0,4
35,3
0,61
72
9,1
4,3
109
5
200
0,2
0,7
3
7
130
82 / 42
75 / 20
20
2,43
0,85
230/50
118
+5
24D
40
280/450/750
47-116-09
* Calculated at 70% maximum output
** Calculated on Upper calorific value
Max.
Condensate produced l/h
PH of condensate W
1.2. TECHNICAL INFORMATION

Other manuals for Ariston Type C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston Type C and is the answer not in the manual?

Ariston Type C Specifications

General IconGeneral
BrandAriston
ModelType C
CategoryBoiler
LanguageEnglish

Related product manuals