EasyManua.ls Logo

Armstrong DRV40 - Battery Error; Cable and PCB;PSU Checks; Troubleshooting Actions for Battery Issues; Display Issues

Armstrong DRV40
5 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intelligent System Solutions® STEAM AIR HOT WATER
armstronginternational.com
Armstrong Hot Water, Inc. – DRV40-80 Gen. 2 Troubleshoot Guide
221 Armstron
g
Blvd.
,
Three Rivers
,
Michi
g
an 49093
U.S.A. Phone:
(
269
)
27
9
-
3602
Fax:
(
269
)
27
9
-
3130
Battery Error
Has the valve been reset
(
i.e.
p
owered off
,
then on
)
?
Check
Yes
No
Reset the valve by
powering down & then
p
owerin
g
back on
Have the batteries been
replaced within last year?
No
Re
p
lace Batteries
No
Ensure all wires are not
pinched & plugs are
connected
Are all cables/wires &
connectors ok?
Yes
Yes
Yes
No
Replace Ele. Housing
No
Re
p
lace Ele. Housin
g
Is the valve PCB
operational and ok?
Is the valve PSU
operational and ok?
Yes
Issue addressed or Contact
Factory @ 269-279-3602
Display Issues
Has the valve been reset
(
i.e.
p
owered off
,
then on
)
?
Check
Yes
No
Reset the valve by
powering down & then
p
owerin
g
back on
No
No
Adjust brightness via
POT adjustment screw on
PCB
Is the lighting/brightness
sufficient?
Yes
Yes
Replace display & keep
original to allow for a
spare in event heat
affects a
g
ain
Is the display
numerals/characters ok?
Issue addressed or Contact
Factory @ 269-279-3602
Key:
PSU = Power Supply GDA = Gear Drive Assembly
PCB = Printed Circuit Board