EasyManua.ls Logo

Armstrong The Brain DRV25 User Manual

Armstrong The Brain DRV25
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
Armstrong International
221 Armstrong Blvd., Three Rivers, Michigan, 49093 - USA
armstronginternational.com/brain
The installation and service must be performed by a qualied installer.
For further information, please call our technical department Toll Free at 1-888-468-4673.
The Brain
®
DRV25
Digital Recirculation Valve
Keep this manual with installation
for future reference.
Recirculating Valve
E357437
Question and Answer IconNeed help?

Do you have a question about the Armstrong The Brain DRV25 and is the answer not in the manual?

Armstrong The Brain DRV25 Specifications

General IconGeneral
BrandArmstrong
ModelThe Brain DRV25
CategoryControl Unit
LanguageEnglish

Summary

Safety

Installation

General Installation Guidelines

Instructions for qualified personnel and compliance with plumbing codes.

Installation Requirements

Piping Diagrams

Figure 12-1. DRV25 Single Valve Installation

Illustrates the piping diagram for a single DRV25 unit installation.

Figure 13-1. DRV25 Dual Valve Installation

Illustrates the piping diagram for a dual DRV25 unit installation.

Figure 14-1. DRV25 Group Shower Installation

Illustrates the piping diagram for a DRV25 group shower installation.

Installation - DRV25

Power Connection and Initial Checks

Details grounding, power connection, and verifying the initial power-up sequence.

Commissioning Reference

Directs user to follow subsequent instructions for commissioning.

Commissioning

System Preparation and Power-Up

Steps for powering off, flooding the system, and powering on the DRV25.

Mobile App Pairing Procedure

Guides on pairing the DRV25 with the SAGE® mobile app.

Mobile App - Connect to the DRV25

Configure Setpoints

Thermal Disinfection

IMPORTANT! Read and Understand

Stresses reading and understanding the thermal disinfection process and warnings.

Maximum Temperature and Hazard Warnings

Warns against exceeding temperature limits and highlights scalding hazards.

Process Operation and Responsibilities

Details disabled alerts, supervisor duties, and cool down procedures.

Disinfection Quick Start Guide - 1

Step 1-2: Parameter Verification and Navigation

Verify setpoints/timeout and navigate to the Disinfection tab.

Disinfection Quick Start Guide - 2

Preventative Maintenance

DRV25 Spare Parts

Disassembly Safety Warnings

Lists critical safety precautions before disassembling the DRV25.

Isolate Supplies and Cool Down

Instructs to isolate electrical/water supplies and allow hot water to cool.

Troubleshooting

DRV25 Errors Overview

General section on DRV25 error codes and their meanings.

Specific Error Troubleshooting

Covers battery, motor, PCB, thermistor, and over-temperature errors.

Common Faults and Solutions

Lists common operational problems and their likely causes and solutions.

DRV25 LED Indications

DRV25 Errors

Battery Error Checks

Provides checks for discharged, disconnected, or corroded batteries.

Emergency Mode / Motor Error

Symptoms and Maintenance

Indicates required maintenance and lists symptoms of motor/cable loom failure.

Troubleshooting Motor Issues

Guides on checking connections, dirt, motor, and belts for motor errors.

PCB Errors

Terminal PCB Errors

Lists terminal errors indicating irreversible PCB failure.

Recoverable PCB Errors

Lists recoverable errors potentially fixable by power cycling the unit.

Open Circuit Thermistor

Troubleshooting Thermistor Issues

Guides on checking connections, thermistors, and replacing the thermistor loom.

Over Temperature

Troubleshooting Over Temperature

Guides on checking temperature limits, seals, mechanism, and thermistor loom.

Common Faults

Blend Temp Rise in Zero Demand

Addresses blend temperature rise during zero demand and its causes.