HEX
Commissioning
Commissioning must be carried out in accordance with these instructions by designated, qualied and competent
personel.
Ensure that the system is powered and
the display on the Electronics Module is
illuminated.
Make sure the hot and cold inlet supplies
are at their designated pressures and
temperatures.
Close all the mixed water outlets and turn on
the circulating pump.
Ensure the system is powered off and the 4 pin plug is unplugged on the electronics module.
Flood the system in the following sequence:
• Open the cold water supply isolation valve(s).
• Open the outlet ow isolation valve(s).
• Open the hot water supply isolation valve(s).
• Once ooded, connect and secure the 4 pin plug to the electronics module.
Close and secure the Electronics Module with the 2 x 4mm hexagon socket screws provided.
Note! The Electronics Module must be closed for the DRV40 to function.