EasyManua.ls Logo

ARPWAVE Rx100 - User Manual

ARPWAVE Rx100
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CONFIDENTIAL MATERIAL
DO NOT DUPLICATE
7/30/2019
Accelerated
Recovery
Performance
Operations Manual
Table of Contents
Introduction ............................................................... 3
Features & Benefits ............................................... 3
Indications for Use ................................................. 3
Training .................................................................. 3
Device Classification & Markings ........................... 4
Contraindications, Warnings, & Precautions .......... 5
Cautions ................................................................ 6
ARP Rx100 Specifications .................................... 7
Operation .................................................................. 8
Terminology ........................................................... 9
Description of the Operator Controls ..................... 9
Operation of Display Screens .............................. 10
Power Supply / Battery Instructions ..................... 18
Pad Placement Instructions / Techniques ........... 20
Sponge and Pad Information ...............................
22
Care & Maintenance ............................................ 23
Service & Parts .................................................... 24
Troubleshooting
Guide ......................................... 25
Warranty
Information ........................................... 28
Exclusive Distributor Of Rx100
ARPwave, LLC
7721 145
th
St. West
Apple Valley, MN 55124-7516 USA
Phone: +1 952-431-9708
Fax: +1 952-431-9723
www.ARPwave.com
ARP Manufacturing, LLC
7747 E. Southern Ave.
Mesa, AZ 85209 USA
Phone: +1 303-713-0605
Fax: +1 303-713-0581
Patent Nos. D603,971 S; 9,302,102
ISO 13485:2016
001086 REV I
2
1

Questions and Answers

  • D
    Deborah NunezAug 12, 2025
    How to fix ARPWAVE Rx100 Medical Equipment if the machine won’t power on?
    • L
      Lauren SilvaAug 12, 2025
      If the ARPWAVE Medical Equipment machine won’t power on, first, charge the battery or use the external power supply (AC adapter). Then, check the connection at the wall outlet. Finally, reposition the power plug to ensure a secure connection at the input power jack.
  • G
    gregorywalkerAug 15, 2025
    What to do if my ARPWAVE Rx100 Medical Equipment powers off during a session?
    • C
      Christopher HernandezAug 16, 2025
      If the ARPWAVE Medical Equipment powers off (the touch screen goes blank) during a session, charge the battery or use the external power supply (AC adapter). You may also need to reposition the power plug to ensure a stable connection at the input power jack.
  • J
    jonescoreyAug 20, 2025
    Why is the sensation intermittent in the pads of my ARPWAVE Medical Equipment?
    • A
      Allison MartinezAug 20, 2025
      To resolve intermittent sensation in the pads of your ARPWAVE Medical Equipment, ensure the Duty Cycle is set to CONT (continuous) and not cycling on and off.
  • C
    Cristian WilliamsAug 25, 2025
    What to do if patient discomfort after switching polarity on ARPWAVE Rx100 Medical Equipment?
    • D
      Danielle WileyAug 25, 2025
      If a patient experiences discomfort after switching polarity on the ARPWAVE Medical Equipment, turn the 'Output Power' down, switch the polarity, and then return the power setting to a level tolerable by the patient.
  • R
    Richard BradyAug 28, 2025
    What to do if patient discomfort after changing Main Pulse Frequency on ARPWAVE Medical Equipment?
    • S
      Stephen MillerAug 28, 2025
      If a patient experiences discomfort after changing the Main Pulse Frequency on the ARPWAVE Medical Equipment, reduce the 'Output Power', switch the Main Pulse Frequency, and then adjust the power setting back to a level that is tolerable for the patient.
  • J
    Jacqueline GuerreroSep 1, 2025
    How to fix ARPWAVE Rx100 if main pulses turn on immediately?
    • J
      Jenna HollandSep 1, 2025
      If the main pulses turn on immediately instead of gradually on your ARPWAVE Medical Equipment, deactivate Sub-second mode by following the instructions on page 15.
  • M
    Megan BlairNov 6, 2025
    What to do if there is no sensation in the pads of my ARPWAVE Rx100?
    • K
      Kathleen WhitneyNov 6, 2025
      If you experience no sensation in the pads when using the ARPWAVE Medical Equipment, ensure the power switch is ON. Check if your authorized time credits are exhausted and request additional time if needed. Secure all connections, including the unit to the power supply box and the box to the power cord. Verify the wall outlet is functional and the wall switch is on. If using battery power, attach the battery to the DC receptacle. Test and replace any damaged or worn conductive pads. Reconnect any disconnected cables, ensuring the 'Output Power' is at zero before slowly adjusting it. Check cable connections and replace faulty cables. Adjust the 'Balance' to direct power to the correct jack. Confirm the 'Output Power' is appropriately turned up. Adjust the frequency and 'Output Power' if the...

Summary

Introduction

Features and Benefits

Highlights the blend of two signals and patient participation for effective therapy.

Indications for Use

Lists conditions for which the ARP Rx100 is approved for practitioner use.

What is the ARP Rx100?

Explains the signal type and polarity used by the ARP Rx100 device.

Device Classification and Markings

Safety and Precautions

Contraindications

Lists conditions and patient groups for whom the device should not be used.

Warnings

Provides essential warnings for safe and effective operation of the device.

Precautions

Advises on necessary precautions for specific patient conditions and scenarios.

Adverse Reactions

ARP Rx100 Specifications

Operation

Operator Controls Description

Operation of Display Screens

Startup Screen

The first screen displayed after powering on the device.

Timer Screen (Zero Time Value)

Initial timer screen display when time value is 00:00.

Power Supply and Battery Instructions

The AC Adapter

Details the operation and safety guidelines for the AC adapter.

Using Battery Power

Instructions for installing and using the lithium-ion battery.

Battery Recharging

Procedure for recharging the lithium-ion battery.

Pad Placement Instructions and Techniques

Troubleshooting Guide

Warranty Information

ARPWAVE Rx100 Specifications

General IconGeneral
CategoryMedical Equipment
ModelRx100
Channels2
Power SupplyAC 100-240V, 50/60 Hz
Pulse Width50 µs to 500 µs