Auto Mode Setting
1. Power on the device, then press AUTO button.
2. S1 will be shown on the top left corner, input the 3 settings - TEMP, TIMER and POWER
(as in manual mode, with “+” and “-“).
3. After having entered the settings for the 1st step, press AUTO button again, then enter into 2nd step
setting. 3rd to 9th steps are set as 1st and 2nd. For each step (3-9) press the AUTO button to confirm and
go to the next step.
4. Once TEMP is set to 100°C, it automatically changes from MASHING to BOILING.
5. Setting hop reminder in boiling process: After setting the TEMP, TIMER and POWER for boiling, press AUTO.
Set time for hop 1 using “+” and “-“. Press TIMER button for 2nd, 3rd, … hop reminder. For example: 60
minutes boiling and after 10 minutes first hop addition, the hop reminder TIMER should be 50 minutes.
6. When you have entered the required steps (up to 9), press the START button to confirm the above step
settings. The brewing process will start. The current step will blink in the upper left corner.
7. If 9 steps are too much for your recipe, set all temperatures below boiling by pressing TEMP button after
your last step. The programme only supports one boiling setting in each recipe. You can adjust the boiling
power during operation anytime.
MANUAL/PAUSE
Press START and the machine starts working, you will see an “H” flashing in the top left corner of the display.
While the machine is heating up, press MANUAL/PAUSE. The Edit page will be visible on the display.
Change TEMP, POWER AND TIMER values, to confirm: press MANUAL.
After editing press MANUAL/PAUSE for 5 seconds.
You will then hear a ringing signal, which indicates that data were saved successfully.
TEMP
POWER TIMER
When pressing STOP,
the machine will stop.
ATTENTION:
Temperature must be
set higher
than the current value
on the display
Next program,
Start with
MANUAL/PAUSE