EasyManua.ls Logo

Artel NCA115-2A - Maintenance Schedule; Periodic Maintenance Table

Default Icon
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 of 36
EN
Maintenance and cleaning
All cleaning of all parts must be carried out with the pellet insert
completely cold and unplugged to avoid burns and thermal shock. The
pellet insert does not need much maintenance if used with certied
quality pellet. The need for maintenance varies depending on the conditions of use
(switching on and off repeatedly) and depending on the performance required.
◊ by the user
• by the authorised qualied technical assistance
Every 1200 hours of work the electronic board sends a warning signal and the
display will show “
SERVICESERVICE”. This indicates the need for a thorough cleaning of the
pellet insert by a CAT. The lack of such cleaning could result in failure of the pellet
insert and poor combustion, thereby resulting in a lower yield.
Parts
Everyday
Every 2-3
days
Every week
Every 15
days
Every 30
days
Every 60-
90 days
Every year /
1200-1400 h
Brazier
Pulizia raschiatore (ove
presente)
Cleaning ash collection
compartment
Cleaning ash tray
Cleaning the door and
glass
Cleaning the interior heat
exchanger /
smoke fan compartment
Cleaning complete
exchanger
Clean "T" to exhaust
Flue
Door gasket ash
Internal parts
Flue pipe
Electromechanical
components