950-0073-00, Rev. B English
950-0073-00 B SM, English, Arthrex Synergy UHD4 System 1 of 74
Synergy
UHD4
System
Service Manual
AR-3200-0020
AR-3200-0021
AR-3210-0018
AR-3210-0021
AR-3210-0022
AR-3210-0023
AR-3210-0025
AR-3210-0026
AR-3210-0028
AR-3210-0029
AR-3210-0030
The Arthrex Synergy
UHD4
System Camera Control Unit and
Camera Head Service Manual provides important information
for the safe operation and service of all components of the
Synergy
UHD4
Camera System, including accessories. Read
this Service Manual thoroughly prior to using this system and
keep it in an easily accessible place for use by all operating
personnel. Read and follow all safety warnings, cautions and
precautions.
Arthrex, Inc.
1370 Creekside Blvd.
Naples, FL 34108, USA
+1 (800) 934-4404
Technical Support
1-888-420-9393
EC
REP
Arthrex GmbH
Erwin-Hielscher-Strasse 9
81249 München, Germany
+49 89 909005-0

Table of Contents

Other manuals for Arthrex AR-3200-0020

Questions and Answers

  • V
    vgarrettAug 14, 2025
    What to do if there is no video image on the Arthrex Control Unit monitor?
    • A
      Austin OrtizAug 14, 2025
      If there's no video image on the monitor, ensure the Control Unit and monitor are plugged in and powered on. Confirm all cable connections are correct, rerouting video cables if needed, and check for any cable damage, replacing them if necessary. Also, ensure the camera head cable connector is fully inserted into the Control Unit's camera head receptacle. If the issue persists, try replacing the camera head with a working one to see if the original camera head or cable is faulty and needs repair.
  • S
    Sean BrownAug 17, 2025
    How to fix intermittent picture on Arthrex AR-3200-0020 Control Unit?
    • C
      Cynthia MatthewsAug 17, 2025
      To fix an intermittent picture, first, reinsert the camera head connector card edge fully into the CCU camera receptacle. Flex the video and power cables; if the picture is affected, inspect and replace the cables as needed. If flexing the camera cable affects the picture, it may need factory repair or replacement.
  • S
    Sarah WalkerAug 20, 2025
    What to do if Arthrex AR-3200-0020 Control Unit camera does not power up?
    • Q
      qbrownAug 21, 2025
      If the camera doesn't power up and the standby LED doesn't illuminate, ensure the power cord is plugged into both the CCU and a properly grounded receptacle. If it is, try replacing the power cord, as it may be faulty.
  • B
    bwuAug 25, 2025
    Why Arthrex AR-3200-0020 Control Unit camera will not white balance?
    • J
      Jeffrey RodriguezAug 25, 2025
      If the monitor indicates “White Balance Fail”, it could be due to too much light, too little light, or the wrong color temperature light. Try moving the scope further away or closer to the white gauze during white balance, or adjust the LED Light Engine brightness accordingly.
  • T
    Terry ColonAug 27, 2025
    What to do if Arthrex Control Unit tablet continually restarts?
    • D
      Danielle DawsonAug 27, 2025
      If the tablet continually restarts or won't progress beyond the Samsung startup screen, first, check the tablet cable and connector for any damage. Also, ensure you're using a Samsung model EP-TA10JWE charger with a minimum of 2.0A charge current and a USB 3.0 charger cable (both connectors) no longer than 6 ft. (1.83 meters). Replace the charger or cable if they don't meet these specifications.
  • J
    jesse67Aug 30, 2025
    How to fix poor color reproduction on Arthrex AR-3200-0020?
    • K
      Kelli MartinAug 30, 2025
      To correct poor color reproduction, white balance the camera head.
  • L
    Lisa PerezSep 3, 2025
    How to fix Arthrex AR-3200-0020 system that does not boot up correctly?
    • B
      Brent WashingtonSep 3, 2025
      If the system doesn't boot up correctly or banners don't display properly, power down the device, wait three minutes, and then restart the system.
  • S
    steven16Sep 6, 2025
    Why Arthrex Control Unit camera head buttons do not function?
    • X
      xdaySep 6, 2025
      If the camera head buttons do not function as programmed, reprogram the camera head buttons. Note that this solution applies only to the Tablet Data Input device option.
  • G
    gardnerbryceSep 9, 2025
    What to do if AR-3200-1013 Tablet will not connect to Arthrex CCU?
    • E
      ehernandezSep 9, 2025
      If the AR-3200-1013 Tablet will not connect to the CCU, update the SynergyUHD4 Software to v4.13.1 or newer.

Summary

Introduction and Safety Information

Warnings and Precautions

Explains the meaning of WARNING, PRECAUTION, and NOTE symbols and their importance.

End of Life and Initial Device Use

Initial Use of the Device

Important considerations and warnings before first-time use of the system.

Synergy System Indicators and Panels

Synergy Front Panel Details

Detailed description of front panel controls and indicators.

Synergy Rear Panel

Camera Heads with Integrated Optics

C-Mount Camera Heads

System Installation and Operation

Installation Procedures

Step-by-step guide for installing the Synergy system components.

Typical System Installation Diagram

Illustrates a standard configuration for connecting system components.

System Setup and Surgeon Settings

System Configuration Settings

Network Configuration

Surgeon Management

Surgeon Preferences Settings

Procedure Preferences

Surgeon Procedure Settings

Scheduling and Starting Cases

Schedule a Surgical Case

Start a Surgical Case

Confirm Surgical Case Details

Camera Head Button Adjustments During Case

End a Surgical Case

System Operation Without Tablet

Camera Control Unit (CCU) Details

Motherboard Functions

Isolation Board Functions

Camera Head Overview

System Programming

Maintenance Overview

Cleaning and Sterilizing Procedures

Procedures for cleaning the LED engine and the CCU unit.

Camera Head Cleaning Procedures

Manual Cleaning Procedures

Camera Head Sterilization

Troubleshooting Common Issues

Annual CCU Maintenance Requirements

Lithium Battery Replacement

Troubleshooting and System Tests

System Test Procedure

Step-by-step guide for performing system tests and checks.

Technical Information

Safety, EMC, and Regulatory Compliance

Details system classifications, certifications, and compliance standards.

System Specifications

Appendix: Detailed EMC Information

IEC 60601-1-2: Electromagnetic Emissions

IEC 60601-1-2: Electromagnetic Immunity

Arthrex AR-3200-0020 Specifications

General IconGeneral
Product TypeControl Unit
Model NumberAR-3200-0020
ManufacturerArthrex
CategoryControl Unit
TypeMedical Device

Related product manuals