Model D1996FI, SS, and HNDL
(DW 95FI)
Page
Date
2000-06
3
PROGRAMS
EXTENDING FAN COOLING TIME
To extend the fan cooling time, press S1 five times then press one of the following:
S5 for 30 extra minutes
S4 for normal fan cooling time
SETTING AN EXTRA RINSE
To add an extra rinse to the Pots and Pans and Normal wash programs, press S2 five times then
press one of the following:
S5 for an extra rinse
S4 for the normal number of rinses
SETTING CHILD-SAFE START FUNCTION
The start function can be reprogrammed so that the button must be pressed in for 3 seconds to start the
programs. To do so, press S4 five times then press one of the following:
S5 to get a prolonged start function or
S4 to get a normal start function
SETTING PUMP-OUT TIME
If it's necessary to reprogram the pump-out time, you can do so by pressing S3 five times then pressing
one of the following:
Press: to get an outlet time of:
S3 20 seconds
S4 25 seconds (factory setting)
S5 35 seconds
S6 45 seconds
S7 85 seconds
SETTING INLET TIME
You can reprogram the inlet time on level controlled and time controlled inlets. To do this, press S5 five
times then press one of the following:
Press: to get an inlet time of:
S3 45 seconds (factory setting)
S4 56 seconds
S5 68 seconds
S6 90 seconds
S7 113 seconds
S8 180 seconds