1. Put the keypad in Program Mode by entering the Installer Code followed by
the “”. The keypad will beep twice and the yellow LED will be on and not
blinking.
2. Enter “(Output) (Code Number) #”.
For example, if you wish to delete the User Code in Code Number “02” for
Output 1 you would enter “1 0 2 #”.
If you wish to delete the User Code in Code Number “3” for Output 3 you
would enter “2 3 #”.
3. Enter “” to exit Program Mode. The yellow LED will begin blinking.
To delete all User Codes enter “8 9 0 1 #”.
Enter a valid User Code to activate the associated Output. The keypad must be
in standby mode (yellow LED blinking).
1. Enter “(User Code) #”.
For example, if the User Code is “1234” you would enter “1 2 3 4 #”.
OPERATION
DELETING USER CODES
The keypad can be programmed to be disabled for 15 minutes after 5 successive
false code entries.
1. Put the keypad in Program Mode by entering the Installer Code followed by
the “”. The keypad will beep twice and the yellow LED will be on and not
blinking.
2. Enter “7 2 5 #”.
3. Enter “” to exit Program Mode. The yellow LED will begin blinking.
To disable the False Code Lockout feature -
1. Put the keypad in Program Mode by entering the Installer Code followed by
the “”. The keypad will beep twice and the yellow LED will be on and not
blinking.
2. Enter “7 6 0 0 #”.
3. Enter “” to exit Program Mode. The yellow LED will begin blinking.
FALSE CODE LOCKOUT
The keypad will generate an alarm instantly if the door is opened without a valid
User Code or Egress Input. The alarm will last for 60 seconds. Door position is
monitored via the Door Position Sensor Input. The alarm will be turned off
immediately with any valid Output 1 User Code entry.
1. Put the keypad in Program Mode by entering the Installer Code followed by
the “”. The keypad will beep twice and the yellow LED will be on and not
blinking.
2. Enter “8 0 1 #”.
3. Enter “” to exit Program Mode. The yellow LED will begin blinking.
DOOR FORCED OPEN ALARM