EasyManua.ls Logo

Assa Abloy Alarm Controls KP-400 - Direct Access to Programming (Dap)

Assa Abloy Alarm Controls KP-400
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
If the Installer Code is forgotten, the Direct Access to Programming (DAP) utility
can be used to put the keypad in Programming Mode.
1. Disconnect the power supply from the keypad.
2. Move the DAP jumper from the OFF to the ON position.
3. Reconnect the power supply to the keypad (keypad will start beeping).
4. Move the DAP jumper from the ON to the OFF position (keypad will stop
beeping and the yellow LED will be on and not blinking. The keypad is now in
Programming Mode.
5. A new Installer Code must now be entered.
6. Enter 0 (4 to 8 digit new installer code) #”. For example, if you wish to
change the Installer Code to 1 2 3 4 you would enter “0 1 2 3 4 #”.
7. The keypad will beep twice indicating that the new Installer Code has been
accepted.
8. Enter ” to exit Program Mode. The yellow LED will begin blinking.
The Green LED is on while Output 1 is activated.
The Red LED is on while Output 2 is activated.
The Yellow LED is described in the table below -
Yellow LED Keypad Status Tone Indicator
On Programming Mode None
1 Blink Successful Key Press 1 Beep
2 Blinks Successful Code Entry 2 Beeps
5 Blinks Error in Code Entry 5 Beeps
Continuous Blinking Standby Mode None
Continuous Blinking DAP Jumper not replaced Continuous Tone
DIRECT ACCESS TO PROGRAMMING (DAP)
LED AND TONE INDICATORS