USER MANUAL
Page - 13
AP1 KEYPAD
Door Control and Monitoring
This application is used to control and monitor
a door. Events, which can trigger alarms, will be
created when the door is forced open or held
open past the specied limit.
Relay 2 can be left unused or can be used to
drive a siren, door holder, door opener or shunt a
security alarm
In this application Inputs 1 and 2 should be set for
monitoring door or gate and RTE respectively.
Two Floor Elevator Control
In this application the AP1 is used to control
access to two oors by using the relays to enable
the oor button. The keypad can be mounted
inside the elevator cab.
Elevator access functionality must be
implemented in the system controller.
Door
Contact
Req to Exit Button
or Motion Sensor
Siren/Door
Holder/Security
Alarm Shunt
AP1
In 1
In 2
Relay 2
Door Strike or
Mag Lock
Relay 1
Third Floor
Elevator Enable
AP1
Relay 2
Second Floor
Elevator Enable
Relay 1
| APPLICATIONS