SL100 Latch Adaptor
Copyright
©
2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
For Installation Assistance, Call 855-594-6989 • www.assaabloyglass.us
2. Tools Needed:
Allen Keys:
5
/
64
",
1
/
8
",
5
/
32
",
3
/
16
",
1
/
4
"
• Flat Head Screw Driver
Vise Grips (Non-marring): Curved Jaw, Straight Jaw
Gasketing (Vertical Ball Joint Removal)
Table of Contents:
1. Parts List ................................................................................1
2. Tools Needed .......................................................................1
3. Applicable on Glass Door Types.....................................1
4. Remove Assembly from the Door ................................2
5. Removing Old Latch Assembly ......................................2
6. Installing SL100 Latch Adaptor ..................................3-4
7. Install Assembly on the Door ........................................5
8. Strike Installation ...............................................................5
9. Final Checks ......................................................................6-7
10. Maintenance .....................................................................7
1. Parts List:
• SL100 Latch Adaptor • Lubricant Packet
• Rockwood Manual Strike • Threadlocker
• Latch-Actuator Gauge • Fasteners
3. Applicable on Glass Door Types:
A BP P
NOT TO SCALE
Question and Answer IconNeed help?

Do you have a question about the Assa Abloy SL100 and is the answer not in the manual?

Summary

Parts List

Tools Needed

Applicable Glass Door Types

Remove Assembly from Door

Removing Old Latch Assembly

Installing SL100 Latch Adaptor

Install Assembly on Door

Strike Installation

Final Checks

Latch Engagement

Verify minimum and maximum latch engagement for proper door function.

Tube-Strike Gap

Check the gap between the tube and strike against specified limits.

Align Actuator Gauge

Install and align the Latch and Actuator Gauge for correct operation.

Adjust Bolts

Maintenance

General Maintenance Instructions

Periodically check fasteners, reapply threadlocker, and lubricate the latch as needed.

Overview

The SL100 Latch Adaptor is a component designed for use with glass door systems, specifically for adapting existing panic devices to a new latch mechanism. This adaptor is part of a comprehensive system provided by ASSA ABLOY, a global leader in door opening solutions, and is intended to enhance security, safety, and convenience for end-users. The installation process involves a series of steps for removing an old latch assembly and integrating the new SL100 Latch Adaptor, followed by strike installation, final checks, and ongoing maintenance.

Function Description:

The primary function of the SL100 Latch Adaptor is to facilitate the conversion or upgrade of existing panic devices on glass doors to a new SL100 latch system. It acts as an intermediary component, threading into the linkage rod of the door's internal assembly. This adaptor ensures proper engagement and operation of the latch mechanism within the door's tube, allowing for secure locking and reliable panic release. The system is designed to work with specific glass door types, including "A," "BP," and "P" configurations, as indicated by diagrams in the manual. The adaptor's design allows for precise adjustment of the latch height and engagement, which is crucial for optimal performance and security.

Important Technical Specifications:

The installation and operation of the SL100 Latch Adaptor rely on several technical specifications and measurements:

  • Latch Engagement: The minimum latch engagement is specified as 1/8" (3.180 mm), while the maximum latch engagement is 1/4" (6.35 mm). These measurements are critical for ensuring the latch properly secures the door within the strike.
  • Latch Height Adjustment: The latch height, when sticking out of the tube, should be adjusted to 3/4". This adjustment is made by turning the latch clockwise to decrease height and counter-clockwise to increase height.
  • Thread Engagement: When attaching the SL100 Latch Adaptor to the linkage rod, approximately 3/4" of the adaptor's thread should be engaged in the linkage rod.
  • Tube-Strike Gap: The system specifies both minimum and maximum tube-strike gaps, which are important for proper door closure and latch alignment.
  • Strike Dimensions (Single Door):
    • Overall width: 4 1/8"
    • Height from centerline to top: 1 1/2"
    • Height from centerline to bottom: 1 1/2"
    • Distance from edge of door to strike centerline: 2 3/4"
    • Centerline of 1/2" Glass Door: 2 3/8"
    • Centerline of 3/4" Glass Door: 2 1/4"
    • Strike Shim thickness: 1/16"
  • Strike Dimensions (Double Door):
    • Overall width: 12 7/8"
    • Height from centerline to top: 1 1/2"
    • Height from centerline to bottom: 1 1/2"
    • Distance from edge of door to strike centerline: 5/16" (both sides)
    • Centerline of 1/2" Glass Door: 2 3/8"
    • Centerline of 3/4" Glass Door: 2 1/4"
    • Strike Shim thickness: 1/16"
  • Adjustable Stops: The adjustable stops are secured by 8-32 Set Screws. The strike is attached to the header using Socket Cap Screws (5/16"-18).
  • Tools Required: A specific set of Allen keys (5/64", 1/8", 5/32", 3/16", 1/4"), a flat head screwdriver, and non-marring vise grips (curved jaw, straight jaw) are necessary for installation. Gasketing may be needed for vertical ball joint removal.

Usage Features:

The SL100 Latch Adaptor system is designed for specific applications on glass doors, offering features that ensure both functionality and ease of use:

  • Compatibility: Applicable on "A," "BP," and "P" glass door types, indicating its versatility across common glass door configurations.
  • Adaptability: Allows for the adaptation of existing panic devices, providing a cost-effective solution for upgrades without replacing the entire door system.
  • Precise Adjustment: The ability to adjust latch height and engagement ensures a snug fit and proper operation, preventing rattling and ensuring secure closure.
  • Strike Installation: The manual provides detailed diagrams and measurements for installing the Rockwood Strike on both single and double doors, including the use of shims to compensate for tube-strike gaps.
  • Actuator Gauge: The inclusion of a Latch & Actuator Gauge is a key feature for ensuring correct alignment of the panic device assembly. This gauge helps verify that the latch and actuator components are properly positioned, which is critical for the device's functionality and safety. If the gauge does not fit, realignment is required, and the panic device should not be operated.
  • Adjustable Bolts: The system includes adjustable bolts for fine-tuning the door's closure. This allows for precise control over the gap between the latch face and strike face (approximately 1/16" play) and ensures the retractable latch engages automatically. Adjustments can also prevent the door from rattling or ensure it stops correctly on rubber stop pads.

Maintenance Features:

Regular maintenance is crucial for the long-term performance and reliability of the SL100 Latch Adaptor system:

  • Fastener Checks: Periodically, all fasteners should be checked to ensure they are not loose. If any fasteners are found to be loose, threadlocker should be reapplied, and they should be tightened as necessary. This prevents components from coming undone due to vibrations or repeated use.
  • Lubrication: The latch mechanism requires lubrication. The manual specifies applying lubricant, provided with the Latch Adaptor, to both the front and back faces of the latch. This helps reduce friction, ensures smooth operation, and extends the lifespan of the latch.
  • Alignment Verification: Although not explicitly listed under "Maintenance," the "Final Checks" section, particularly the use of the Latch & Actuator Gauge, implies a need for periodic verification of alignment. If the gauge no longer fits, it indicates a potential misalignment that needs to be addressed, which can be considered a maintenance task to ensure continued proper function.
  • Rubber Stop Pads: The door should come to rest on the rubber stop pads. Regular inspection of these pads for wear and tear can help maintain proper door alignment and prevent damage to the door or frame.

The SL100 Latch Adaptor system is a well-engineered solution for glass door panic devices, emphasizing precision in installation and the importance of ongoing maintenance to ensure security, safety, and durability.

Assa Abloy SL100 Specifications

General IconGeneral
BrandAssa Abloy
ModelSL100
CategoryIndoor Furnishing
LanguageEnglish