See complete manual for further information on:
• Installation and calibration of pH, ORP, ppm and temperature sensors
• Maintenance of peristaltic pumps

or the installation.
󰀩
tion of free chlorine in the water and reduce the build-up of limescale in the pool.
3. If the pool is to be used immediately, chlorine treatment should be carried out. Initial dose:
2 mg/L trichloroisocyanuric acid.

24 hours to ensure complete dissolution of the salt.
5. Start the saline electrolysis system, setting production at a value between the recom-
mended levels of free chlorine (0.5–2 ppm).
Initial Start-Up Pool water balance
The water must be maintained within the follow-
ing parameters:
• Total alkalinity between 60 and 120 mg/L (ppm)
• pH between 7.2 and 7.6
• Free chlorine between 0.5 and 2 mg/L (ppm)
• Chlorine stabiliser between 25 and 30 mg/L
(ppm). In pools that are exposed to strong sun-
shine or intensively used, it is advisable to main-
tain a level of 25–30 mg/L of stabiliser (isocya-
nuric acid).
Check and maintain correct water balance
throughout the season.
Heat
AUX 2
AUX 1
AUX 1
Heat
AUX 2
AUX 1
pH PUMP
AUX 2
230Vac
230Vac
100%10%
STOP ClON
FLOWOK
BALASTOK
<3V
>3V
HEAT
LEVEL
OK
OK
ON
STOP Cl
LEVEL
R4
INTERLOCKS
R1
R2
R3
-
-
+
+
(<0.5 A)
(<1.6 A)
230Vac
(<0.5 A)
pH-
pump
Use of Relay Box recommended (SKU:72454)
See complete manual for further
information on:
• pH and ClmV/Clppm menu
• Relay menu (R1-R4)
1) Wi-Fi status LED
2) Statistics menu

4) Information menu
5) Relay menu
6) Alarm LED
Choose language
Cl set point
pH set point
Electronic board connections
Main screen and functions
7) pH
8) ORP / Clppm
9) Sensors (temperature /
salinity)
10) Bluetooth connectivity
11) Home menu
12) Relay status
E
li
t
e
Co
nn
e
ct
RELAY PROGRAM-
CONTROLLED
ON
OFF
PUMP AND TREATMENT
SYSTEM PROGRAM-CON-
TROLLED
Blue
Green
Red
PUMP AND TREATMENT
SYSTEM ON
PUMP AND TREATMENT
SYSTEM OFF
Disinfection
treatment, Cl &
pH sensors
Blue
Green
Red
TREATMENT AND PUMP CONTROL
27.2
°C
OK
12:15
750
725
ClmV
123
7.25
7.60
pH
FLOW
27.2
°C
OK
12:15
750
725
ClmV
123
7.25
7.60
pH
FLOW
27.2
°C
OK
12:15
750
725
ClmV
123
7.25
7.60
pH
FLOW
27.2
°C
OK
12:15
750
725
ClmV
123
7.25
7.60
pH
FLOW
27.2
°C
OK
12:15
750
725
ClmV
123
7.25
7.60
pH
FLOW
Elite
Connect
1
2
3
4
5
6
7
8
9
10
11
12
R4R3R2R1
720
Screen
Language
Sound

Touch
100
ENG
7.60
pH Clppm Sens
pH Clppm Sens
Screen
Language
Sound

Touch
100
ENG
ENG
Language
ENG
SAVE
EXTERNAL DEVICES CONTROL
3 X Output 230 Vac
OUTPUT
FREE
POTENTIAL
4 X OUTPUT FREE POTENTIAL
(Loop max 24V 1A AC-DC)
4 X INPUT FREE POTENTIAL
(Loop 0V)
27.2
°C
OK
12:15
750
725
ClmV
123
7.25
7.60
pH
FLOW
Cl
pump

Related product manuals