- 37 -
7.2.12 Auto Mode
There are 3 modes for the unit, Heating only, Auto mode(heating and cooling switch), Cooling only.
You can switch Heating only and Auto mode by pressing for 5 seconds, no matter the unit is on or off.
Operation logic of Auto Mode
Set water temperature
(Tset)
Current water in temperature
(Tset +2)
Current working
mode
After 3 minutes or
above, it will switch to
Tset (eg: 28)
Tset +2 (eg:30)
Heating mode
Cooling mode
Tset (eg: 28)
Tset-2(eg: 26)
Cooling mode
Heating mode
Both lights are on
Heat Light On