EN 11
1. Fix the oven on both sides using screws.
2. After installation, remove the vinyl
protective film from the door to the
appliance and the protective film from the
interior surfaces of the oven.
Connecting to the mains power supply
• Electrical connections must be made as
per the connection plate fixed to the back
of the appliance by an electrical fitter who
must ensure that the appliance has been
connected up in accordance with fitting
instructions and local regulations.
• Where the appliance is not connected to
the mains electricity supply by a plug, an
omni polar cutout device (with a contacts
gap of at least 3 mm) must be fitted on
the supply side of the connection to meet
safety requirements.
Note
• When the power is connected, the electronics of the oven are
initialised; this neutralizes the lighting for a few seconds. The
electric cable (H05 RR-F or H05 VV-F, Min. 1.5 m, 1.5~2.5 mm²)
must be long enough for it to be connected to the built-in oven
standing on the floor in front of its unit.
Open the back cover of the oven at the bottom (using a flat-bladed
screwdriver) and completely unscrew the connection screw and
the cable clamp before fitting conducting wires into the appropriate
terminals.
• The earth wire must be connected to the (
) terminal of the oven.
• If the oven is connected to the power supply by a plug, this must
remain accessible once the oven has been fitted.
• We cannot accept any liability in the event of an accident resulting
from non-existent or faulty earthing.
INSTALLATION AND CONNECTION
Live
Neutral
Earth