K SERIES CHILLERS
KT1
STANDARD MODELS
INSTRUCTION MANUAL
Issue 3.2

Questions and Answers

  • T
    Timothy McintoshAug 3, 2025
    Why is my ATC K-Series not cooling properly?
    • T
      Trevor SmithAug 3, 2025
      Poor cooling in your ATC Chiller is almost always caused by a blocked condenser. Clean it with a soft brush or vacuum cleaner with a brush attachment. If the problem continues, high ambient temperature or excessive load applied to the unit may be the cause. Check these factors.
  • T
    taylorhannahAug 9, 2025
    What to do if my ATC K-Series Chiller is making noisy operation with high fluid pressure and/or low flow?
    • E
      Edward AndersenAug 9, 2025
      To address the noisy operation, high fluid pressure, and/or low flow in your ATC Chiller, clean the fluid path with a weak detergent solution, flush, and replace the fluid with the correct Hexid fluid. Also, check the pump filter (if fitted), ensure there are no restrictions in the pipe work, and verify that the operating coolant pressure is not set too low.
  • H
    hollowayanthonyAug 15, 2025
    How to clean fluid lines becoming fouled brown or green in ATC Chiller?
    • J
      Julie ScottAug 15, 2025
      If the fluid lines in your ATC Chiller are becoming fouled brown or green, it's likely due to algae contamination. Clean the system with a weak detergent solution, replace the fluid lines with opaque (ideally black) lines to inhibit algae growth, and use Hexid fluid.
  • A
    Alyssa McdonaldAug 21, 2025
    What to do if ATC K-Series Chiller compressor is not running, but fan is running?
    • S
      Sheryl WolfeAug 21, 2025
      If the compressor in your ATC Chiller is not running but the fan is, the compressor’s internal protection has likely been activated, usually due to high ambient temperature. Check that the condenser is clean, the ambient temperature is not too high, and there has been no temporary power failure.
  • S
    Samuel MitchellAug 28, 2025
    How to improve poor fluid flow in ATC K-Series Chiller?
    • J
      Joseph CookAug 28, 2025
      To improve poor fluid flow in your ATC Chiller, flush the system with clean water and replace the fluid with Hexid.

Summary

Introduction

Safety

General safety warnings and precautions for operating the chiller unit.

Unpacking

Procedures for checking and unpacking the chiller unit from its packaging.

Site requirements

Environmental and physical requirements for proper chiller installation.

Warranty registration

Information and process for registering the product warranty for support.

Installation

Voltage selection

How to set the voltage selector switch on the chiller to match the site's electrical supply.

Coolant filling

Step-by-step guide for filling the chiller with appropriate coolant fluid.

Operation

Changing the Set Point

Procedure for adjusting the set point and understanding the controller display and alarms.

Maintenance and service requirements

Troubleshooting

Common symptoms, causes, and solutions for troubleshooting chiller issues.

Return of goods procedure

Dimensions and performance

EC Declaration of Conformity

ATC K-Series Specifications

General IconGeneral
BrandATC
ModelK-Series
CategoryChiller
LanguageEnglish