17
To enter Manual mode touch the hand key, then using the and keys
enter the amount of time you want to force the radiator on or off.
First the number of days is selected; enter between 0 and 365 days and
confirm with the OK key. If you only want a few hours, touch OK to enter 0
days.
The menu then moves to the number of hours selection. The user is able
to enter the amount of time to operate in 1 minute increments up to 1 hour,
after which time the steps increase to 30 minute increments.
When the total desired time is entered confirm with the OK key.
Please note the default minimum time is 30 minutes, however this can be decreased using the
key.
Finally, the desired temperature can be set by the and
keys, any temperature between 7°C to 30°C (in steps of 0.5ºC)
can be entered. Shutdown mode can be entered from either
7°C or 30°C by entering or keys once from each extreme.
Shutdown is indicated by 4 dashes on the screen.(- - - -). When
the desired temperature is entered confirm with the OK key.
The screen will show “DONE”
If no key is touched within 30 seconds before final confirmation, or the MODE key is touched,
the radiator will return to the previous mode of operation.
The selected time will remain on the display and count down until it is finished.
Although you cannot change the set time, it is possible to change the set-point
temperature during the operation of manual mode.
Once the set time has elapsed, the radiator will automatically return to the
previous mode of operation
To exit manual mode at any time, touch the MODE key and the radiator will
return to the previous mode of operation.
In the case where the power is disconnected to the radiator, the manual mode settings will be
saved and the remaining time will count down even though the heater is powered-off.
Open Window function
When the Open Window mode is enabled in the configuration menu the
system automatically switches off the radiator when it detects a sudden
drop in temperature (4°C in 20 minutes). This is normally caused when a
window or door is opened to the outside without turning off the radiator.
When the Open Window mode has activated it is indicated on the
display by a single screen with an open window.
In order to enable the heating again the user must touch the MODE key.
The heater will then return to the previous mode of operation.
Note: In installations where this function is activated very frequently, it may be appropriate to
keep it disabled.
* This function is taken into account by Directive 2009/125/EC regulations and will give
the unit more efficiency during operation.