4. Installation semi cased (1 duct for air exit).
non heated room with ambient temperature > C and insulated to the
heated rooms of the dwelling.
Parameter « Duct » to be set on « Interior/Exterior ».
Recommended room = underground or partially underground, room where
average yearly temperature is > 10° C°.
The pressure reduction in the room generated by the air extraction causes fresh air entry through
doors and windows. Plan an air entry 125mm) from outside to avoid air sucking from heated
living area.
In winter time the renewed air can cool the room.
Keep a free space of 450 mm in front of electric to allow easy access for maintenance.
Examples :
Garage : recovery of free calories from combustion engine or of domestic
devices
Washing room : reduce humidity of the room and recover lost calories of
washing machine and dryer.
Interior/Exterior
600mm
mini
Installation
Mini
200mm
38