Home
Atlantic
Heat Pump
WOYG112LCT
Atlantic WOYG112LCT Installation And Commissioning Instructions
80 pages
Manual
Specs
Ask a question
To Next Page
To Next Page
Loading...
Installation and
commissioning
instructions
for professionals
to be kept by the user
for future reference
Outdoor unit
Hydraulic unit
WOYG1
12LCT
024200
WOYG140LCT
WOYK1
12LCT
WOYK140LCT
WOYK160LCT
Air/water heat pump
with integrated gas burner
,
split, 2 services
Document n° 1485-
9
~
26
/0
7
/2013
alféa hybrid duo gas
atlantic-comfort.com
The specications of this
equipment may
be modied without prior
notice
Non-contractual document.
FR
EN
IT
DE
EN
ES
PT
2
Table of Contents
Default Chapter
3
Table of Contents
3
Presentation of the Equipment
5
Packaging
5
Definitions
5
General Characteristics
6
Description
11
Operating Principle
13
Installation
15
Installation and Maintenance Rules
15
Filling the Installation with Gas
27
Commissioning Procedure
27
Sealing Test
28
Additional Charge
29
Connecting the Heating Circuit and 15 the Domestic Circuit
30
General
30
Rinsing the Installation
30
Filling and Draining the Installation
31
Connection to an Underfloor Heating Circuit
31
Connection to a Fan Coil Circuit
31
Connection to the Domestic Circuit
31
Condensate Evacuation
31
Gas Change
32
Connecting the Condensate Evacuation Pipe 17 Connection of the Fuel Supply
32
Electrical Connections
33
Room Where to Install 18 Characteristics of the Electrical Power Supply
33
General Remarks on the Electrical Connections
33
Overall View of the Electrical Connections
34
Cross Section of the Cable and Protection Rating
34
Electrical Connections on Outdoor Unit Side
35
Electrical Connections on Outdoor Unit Side (Three Phase Model)
36
Outdoor Sensor
39
Installing a Room Control Unit
39
Commissioning
41
Commissioning the Heat Pump
41
Electric Circuit
41
Heating Installation with
42
Starting the Gas Generator to Check the Combustion
42
Heating Installation with Radiators
42
Hydraulic Circuit: 41 During a Gas Check
43
Gas Circuit: 41 Heating Installation with Radiators
43
Underfloor Heating Circuit
43
Configuring Room Thermostat (T55 or T58)
44
Configuration of the Room Control Unit (T75 or T78)
44
Regulation
46
Thermostat (Option) 46 General
50
Description of the Display 48 Setting the Parameters
50
Setting (Settings, Diagnosis, State)
50
Electrical Wiring Diagrams
62
Fault Diagnostic
65
Faults Displayed on the 3-Phase Outdoor Unit
69
On the Single Phase Outdoor Unit 68 Display Information
70
Servicing of the Installation
71
Servicing of the Gas Heat Exchanger 71 Checking the Outdoor Unit
72
Checking the Hydraulic Circuit 71 Checking the Electrical Circuit
72
Servicing the Evacuation Pipe 72 Checking the Combustion Parameters
72
Servicing the Tank
72
Draining the Hot Water Tank
72
Descaling
72
Maintenance
73
Draining the Hydraulic Module 73 ACI Check
73
Directional Valve
73
Values to be Given to the User
73
Start-Up Procedure
74
Commissioning Assistance "Check List" 74 Configuration File
76
Before Starting 74 Technical Commissioning Instructions
77
Other manuals for Atlantic WOYG112LCT
Installation And Operating Manual
72 pages
Maintenance Document
58 pages
Need help?
Do you have a question about the Atlantic WOYG112LCT and is the answer not in the manual?
Ask a question
Atlantic WOYG112LCT Specifications
General
Type
Air-to-Water Heat Pump
Installation
Outdoor
Capacity
11.2 kW
Refrigerant
R32
Heating Capacity
11.2 kW
Energy Efficiency Ratio (EER)
3.5
Related product manuals
Atlantic WOYG140LCT
72 pages
Atlantic WOYG140LCTA
92 pages
Atlantic WOYG LCT Series
58 pages
Atlantic WOYK160LCT
72 pages
Atlantic WOYA080KLT
84 pages
Atlantic WOYA060KLT
84 pages
Atlantic WOYK140LCTA
92 pages
Atlantic WOYK112LCTA
92 pages
Atlantic WOYA 080 LFCA
92 pages
Atlantic WOYA 100 LFTA
92 pages
Alfea Extensa A.I. R32 WOYA100KLT
88 pages
Alfea Extensa A.I. R32 WOYA060KLT
88 pages