Temperature of the air leaving the outlet valve (approx.), Workplace ˚C 30
Temperature of the air leaving the outlet valve (approx.), Workplace ˚F 86
Temperature of the air leaving the outlet valve (approx.), Workplace Full-
Feature
˚C 30
Temperature of the air leaving the outlet valve (approx.), Workplace Full-
Feature
˚F 86
Refrigerant type, Workplace Full-Feature R410a
GA 18 VSD+
Normal effective working pressure bar(e) 4 7 9.5 12.5
Normal effective working pressure psig 58 102 138 181
Maximum effective working pressure,
Workplace
bar(e) 13 13 13 13
Maximum effective working pressure,
Workplace
psig 189 189 189 189
Maximum effective working pressure,
Workplace Full-Feature
bar(e) 12.75 12.75 12.75 12.75
Maximum effective working pressure,
Workplace Full-Feature
psig 185 185 185 185
Maximum motor shaft speed rpm 4800 4800 4100 3500
Minimum motor shaft speed rpm 1300 1300 1400 1500
Nominal motor power kW 18
Nominal motor power hp 24.1
Total amount of refrigerant, Workplace Full-Feature kg 0.95
Total amount of refrigerant, Workplace Full-Feature lb 2.09
Oil capacity l 14.1
Oil capacity US gal 3.72
Oil capacity Imp. gal 3.1
Oil capacity cu. ft. 0.50
Sound pressure level (according to ISO 2151:2004) dB(A) 64
GA 22 VSD+
Normal effective working pressure bar(e) 4 7 9.5 12.5
Normal effective working pressure psig 58 102 138 181
Maximum effective working pressure,
Workplace
bar(e) 13 13 13 13
Maximum effective working pressure,
Workplace
psig 189 189 189 189
Maximum effective working pressure,
Workplace Full-Feature
bar(e) 12.75 12.75 12.75 12.75
Instruction book
2920 7110 05 111