EasyManua.ls Logo

Atlas Copco GA 18 VSD+

Atlas Copco GA 18 VSD+
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step Action
10 Open the air outlet valve.
Start and run the compressor for a few minutes. Check that the compressor operates normally.
Starting
Control panel Elektronikon
TM
Touch
Step Action
1 Open the air outlet valve.
2 Switch on the voltage. Check that voltage on LED (5) lights up.
3 Press start button (7) on the control panel. The compressor starts running and the automatic
operation LED (4) lights up.
During operation
Keep the panels closed during operation.
When the motors are stopped and LED (automatic operation) is alight, the motors may start
automatically.
When the automatic operation LED is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!
Regularly check the oil level:
Instruction book
2920 7110 05 81

Related product manuals