EasyManua.ls Logo

Atlas Copco GA30C User Manual

Atlas Copco GA30C
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Atlas Copco Stationary Air Compressors
GA5-7-11C-11-15-18-22-30C-30-37-45-55C-55-75-90C and
GA30 W-37 W-45 W-55C W-55 W-75 W-90C W
With Elektronikon I or Elektronikon II regulator
User manual for Elektronikon
®
I and II regulators

Table of Contents

Other manuals for Atlas Copco GA30C

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA30C and is the answer not in the manual?

Atlas Copco GA30C Specifications

General IconGeneral
BrandAtlas Copco
ModelGA30C
CategoryAir Compressor
LanguageEnglish

Summary

Safety Precautions

Installation and Placement

Directives for safe installation and proper unit positioning.

General Safety and Operational Guidelines

Essential safety rules for operating, maintaining, and repairing the unit.

Part 1 - Elektronikon I Regulator

Regulator Overview and Control

Functions like automatic control, protection, and voltage failure restart.

Control Panel and Display

Components and visual interface of the regulator's control panel.

Warnings and Shut-down Conditions

Identification of critical alerts, warnings, and shutdown triggers.

Service Notifications and Screen Navigation

How to handle service alerts and navigate through system screens.

Automatic Control and Restart Functions

Details on compressor loading, unloading, and auto-restart after voltage loss.

Control Panel Functionality

Explains the purpose of each button and LED on the control panel.

Display Screen Elements and Pictographs

Explanation of screen layout, pictographs, and main screen information.

Main Screen and Pictograph Interpretation

Visual guide to the main display and understanding its graphical symbols.

Scrolling Through Screens and Warnings

Navigating through system screens and understanding shut-down warnings.

Shut-down Warning Details

Specifics on element outlet temperature and dewpoint warnings.

Shut-down Conditions and Overload

Causes and indicators for compressor shutdown due to temperature or motor overload.

Service Warnings and Screen Navigation

Handling service alerts and browsing through system displays.

Scrolling Through All Screens

Procedures for navigating all available operational screens.

Accessing Operational Data

Procedures for viewing outlet temperatures, running hours, and loading hours.

Motor Starts and Service Timer Management

Procedures for checking motor starts and managing the service timer.

Automatic Restart and Parameter Access

Configuring automatic restart and accessing parameter settings.

Parameter Settings: Units and Starting Modes

Adjusting units for pressure/temperature and selecting motor starting modes.

Restart Configuration and Control Options

Configuring automatic restart and selecting local/remote control.

Service Timer and Unit Settings

Adjusting service timer and display units for pressure and temperature.

Starting Mode and Parameter Set Modification

Selecting motor starting mode and modifying parameter sets.

Service Timer, Unit Settings, and Parameter Modification

Adjusting service timer, units, and modifying parameter sets.

Starting Mode and Control Selection

Selecting motor starting mode and control options.

Part 2 - Elektronikon II Regulator

General Description and Control

Overview of Elektronikon II features like automatic control and restart.

Control Panel and Interface

Components and functions of the Elektronikon II control panel.

Control Panel Components and Pictographs

Detailed explanation of LEDs, buttons, keys, and pictographs on the control panel.

Function Keys and Their Usage

Explains the role of various function keys for control and programming.

Menu-Driven Program Functions

Structure and purpose of menu-driven programs for compressor control.

Main Screen and Menu Navigation

Understanding the main screen and how to access submenus.

Quick Look at Compressor Status

Procedure to quickly view the current operational status of the compressor.

Status Data Menu Overview

Information regarding protection functions and message resetting.

Status Data Menu Details

Information on no messages, shut-down messages, and warning messages.

Warning and Service Message Handling

Procedures for addressing shut-down warnings, service requests, and general warnings.

Data and Settings Menus

Measured Data and Counter Access

Retrieving measured data and counter values like running hours.

Test Menu and Parameter Modification

Performing display tests and accessing the parameter modification menu.

Parameter and Protection Settings

Modifying Loading and Unloading Pressures

Adjusting pressure band settings for compressor operation.

Modifying Protection Settings

Configuring safety parameters like shut-down and warning levels.

Compressor Element Protection Settings

Modifying temperature settings for element outlet shut-down and warnings.

Service Plan Interval Adjustments

How to modify the running hour intervals for service plans.

Clock Function and Programming

Programming Start/Stop Commands

Setting time-based commands for compressor operation.

Timer Activation and Command Modification

Activating the timer and altering existing programmed commands.

Command Modification Procedures

Steps to modify existing commands within the clock function.

Adding and Deleting Commands

Procedures for adding new commands and removing existing ones from the clock function.

Configuration and Service Menus

Configuration Menu Operations

Reprogramming parameters like time, control modes, and settings.

Service Menu Functions

Resetting service plans and checking service history.

Programmable Settings Overview

Parameter Settings Table

A comprehensive list of all programmable parameters with their min, nominal, and max values.

Protection and Service Plan Parameters

Protection Parameter Details

Specific values for various protection settings like temperature and pressure.

Service Plan Intervals

Nominal running hour intervals for service plans A, B, and C.

Related product manuals