Instruction book
6996 0227 40 83
(1):or yearly, whichever comes first
(2):or every 2 years, whichever comes first
(3):For turbo pumps; for non-turbo application every 48k hrs
(4):When using sythentic oil the indicated number of running hours can be doubled
* In medium and harsh applications an optional 500 hrs oil sample is recommended.
HWHcap option always use sythentic oil and harsh service intervals
The indicated service exchange intervals are valid for standard operating conditions (see section Reference
conditions and limitations) and nominal operating pressure (see section Vacuum pump data). Exposure of the
vacuum pump to external pollutants, operation at high humidity combined with low duty cycles or operation at
higher temperatures may require a shorter service exchange interval. Contact Atlas Copco if in doubt.
Vacuum pumps with optional high water handling capability (humid version) are
recommended for use with Atlas Copco vacuum Synthetic fluid only.
Atlas Copco vacuum Mineral fluid
Element outlet
temperature
Atlas Copco vacuum Synthetic fluid
Element outlet
temperature